Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
112
17 Read error on BMC token Communication with the BMC failed.
Replace the base unit.
18 BMC token transmit checksum error Communication with the BMC failed.
Replace the base unit.
19 Error writing BMC token on download Communication with the BMC failed.
Replace the base unit.
20 Non-Volatile Memory (NVM) token access
error
Communication with the BMC failed.
Replace the base unit.
21 BMC token write error during NVM write
through
Communication with the BMC failed.
Replace the base unit.
22 Error reading BMC token on upload to NVM Communication with the BMC failed.
Replace the base unit.
23 Error reading BMC first boot token Communication with the BMC failed.
Replace the base unit.
24 Primary FIT failed Reflash firmware
25 Secondary FIT failed Reflash firmware
26 Processor Abstraction Layer (PAL)_A warning.
One copy of PAL is bad
Reflash firmware
27 PAL_B warning. Not compatible with at least
one CPU
Update firmware
28 Memory errors detected and page de-allocation
table (PDT) is disabled
Reseat DIMMs, if error persists replace
bad DIMMs
30 Memory required reinterleave to get a good
page 0
Information only, no action required.
31 One or more ranks have chipspare disabled Information only, no action required.
33 One or more memory ranks are mismatched
and deallocated
Check memory installation. Match DIMM
part numbers within each quad.
34 Memory deallocated because of a loading error Check memory installation. DIMMs must
be installed with smallest capacity in the
first quad, an equal or larger capacity in
the second quad, and an equal or largest
capacity in the third quad.
35 Memory is not loaded in recommended loading
order
Check memory installation. DIMMs must
be installed with smallest capacity in the
first quad, an equal or larger capacity in
the second quad, and an equal or largest
capacity in the third quad.
Table A-1 EFI Error and Warning Messages (Continued)
Error
Number
Error/Warning Message Solution