Troubleshooting
Command Line Interface
96
Command Line Interface
The baseboard management controller (BMC) is accessable by means of the BMC console commands or
command line interface (CLI). The commands are similar to the management processor (MP) commands but
are slightly less interactive.
Detailed information on the CLI commands is provided in Chapter 4, “Utilities.
Command Line Interface Menu
The command line interface (CLI) provides the following menu selections:
date: Date display
help: List available commands
ipmi: Send IPMI cmd
loc: System locator LED
passwd: Change password
pc: Power control
pr: Power restore policy
ps: Power status
rs: System reset (through RST signal)
sl: Show logs
sr: Display firmware revisions
tc: System reset (through INIT signal)
exit: Exit
Table 5-21 Power Supply Errors
System
LED
LED 1 LED 2 LED 3 LED 4 Problem Solution
Flashing
Red
Off Red Off Red VRM or power
pod fault
View the SEL for additional
information.
Flashing
Red
Green Red Off Red Power Supply
fault
View the SEL for additional
information. Replace the
power supply if necessary.
Flashing
Red
Green Red Green Red 12V out of range
(power supply
interface fault)
View the SEL for additional
information. If the power
supply interface has failed
it is necessary to replace
the base unit.

Table of Contents

Other manuals for HP Integrity rx1620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx1620 and is the answer not in the manual?

HP Integrity rx1620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx1620
CategoryServer
LanguageEnglish

Related product manuals