Appendix A
111
A Event, Error, and Warning Messages
This appendix contains event, error and warning information for the hp Integrity rx1620 Server system:
• Extensible Firmware Interface (EFI) error and warning messages
• System Event Log (SEL) and Forward Progress Log (FPL) Entries
EFI Error and Warning Messages
EFI error and warning messages are displayed on the console as part of the boot process. They can also be
retrieved via the info warnings EFI command.
Table A-1 EFI Error and Warning Messages
Error
Number
Error/Warning Message Solution
2 Insufficient resources to assign to one or more
I/O devices
Incorrect I/O configuration. Contact the
HP Support center for assistance.
4 Unexpected hardware I/O configuration
Incorrect I/O configuration. Contact the
HP Support center for assistance.
7 No Baseboard Management Controller (BMC)
installed in platform
Ensure the BMC ROM is installed; update
BMC firmware
8 BMC cannot be accessed Check system logs for errors. Replace the
base unit.
9 One or more BMC ports failed Communication with the BMC failed.
Check power. Replace the base unit.
10 BMC system event log is full Clear SEL
11 Platform SCR is bad Contact the HP Support center for
assistance.
12 Set time to BMC SEL failed Communication with the BMC failed.
Replace the base unit.
13 SEL get info failed Communication with the BMC failed.
Replace the base unit.
14 Initial BMC SEL event failed Communication with the BMC failed.
Replace the base unit.
15 Update of BMC buffered data failed Communication with the BMC failed.
Replace the base unit.
16 All Advanced Configuration and Power
Interface (ACPI) BMC ports bad
Communication with the BMC failed.
Replace the base unit.