Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
120
83 03 ipmi/RS req from the CLI thd for CHASSIS_CONTROL_HARD_RESET
00 FA CHASSIS_CONTROL_POWER_DOWN req from the ACPI sensor (S5)
00 D9 CHASSIS_CONTROL_POWER_DOWN req from CPU0 temp sensor
01 0E CHASSIS_CONTROL_POWER_UP req from WakeOnLan sensor
Events Without Sensors
The BMC logs these events with a “sensor number” of 0; there is no matching SDR entry.
Table A-6 Events Without Sensors
Triplet Event data 2 data 3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when
the SEL is 75% full
12:70:64 BMC entering firmware update
mode
12:70:05 SFW flash Inlock
12:70:06 Front panel lock
12:F0:06 Front panel unlock
12:70:64 Firmware update application:
starting component update
12:70:64 Firmware update application:
ending component update
12:70:80 BMC entering special mode Mode Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70:A1 BMC firmware initializing Major FW
rev.
Minor FW
rev.
1D:70:00 BMC Cold Reset
1D:70:01 BMC Warm Reset
1D:70:02 BMC Cold Reset after SDRR
update

Table of Contents

Other manuals for HP Integrity rx1620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx1620 and is the answer not in the manual?

HP Integrity rx1620 Specifications

General IconGeneral
BrandHP
ModelIntegrity rx1620
CategoryServer
LanguageEnglish

Related product manuals