Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
119
For example:
Data2 Data3
80 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_DOWN (“p 0”)
81 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_UP (“p 1”)
80 01 ipmi req from via BT for CHASSIS_CONTROL_POWER_DOWN
0x0D Soft Shutdown and Restart
0x0E Soft Shutdown
Table A-4 Sensor Numbers
Sensor Number Description
0x04 Power Button
0x0E Wake On LAN
0x11-13 Cooling Units
0x40 Power Supply
0xCD-D3, 0xD5-D6 Voltage Sensors
0xD8 Ambient Temperature
0xD9-DA CPU Temperatures
0xFA ACPI
Table A-5 IPMI Origins
Number Source
0x00 block transfer (BT)
0x03 command line interface (CLI)
0x07 intelligent platform management bus (IPMB)
0x08 inter IC (I2C)1
0x09 I2C2
0x0F keyboard controller style (KCS)0
0x10 KCS1
0x11 KCS2
0x1F System Power Thread (Used by Power Restore
Policy)
Table A-3 Chassis Control Commands (Continued)
Command Description

Table of Contents