Event, Error, and Warning Messages
EFI Error and Warning Messages
Appendix A
118
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593 28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START 28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322 28 Feb 2003 16:41:47
System Specific Events
OEM SensorType 12, EventType 71
Missing components are determined at the time of a power-on request, cause a failure in the request, and
cause the event to be logged.
Chassis Control Event Codes
For BMC rev 1.41+, an SEL event will be logged for each ChassisControl event, whether it’s generated by an
IPMI request, or a sensor event.
Later revisions of MP firmware recognize the triplet (12:70:A3) as ChassisControl.
The EventData fields are:
Data1: 0xA3 (indicating OEM data in Data2 and Data3, and OEM offset 3)
Data2:
[7] 0 = Request generated by a Sensor Event
•1 = IPMI request
[6-4] Reserved
[3-0] ChassisControl command
Data3: Sensor Number or IPMI Request Origin
Table A-2 Missing Components
Data 2 Data 3 Missing Component
0x0C-0D Power Pod 0-1
0x20-21 CPU 0-1
0x1E 0x01 Cooling Unit 1
0x1E 0x01 Cooling Unit 2
0x1E 0x03 Cooling Unit 3
Table A-3 Chassis Control Commands
Command Description
0x00 Hard Power Down
0x01 Power Up
0x03 Hard Reset
0x04 NMI/TOC/INIT

Table of Contents