Page #150 background imageLoading...
Page #150 background image
6-12
Configuring and Monitoring Port Security
Port Security Command Options and Operation
Figure 6-5. Example of Adding an Authorized Device to a Port
With the above configuration for port A1, the following command adds the
0c0090-456456 MAC address as the second authorized address.
HPswitch(config)# port-security a1 mac-address 0c0090-
456456
After executing the above command, the security configuration for port A1
would be:
Figure 6-6. Example of Adding a Second Authorized Device to a Port
(The message Inconsistent value appears if the new MAC address exceeds the
current Address Limit or specifies a device that is already on the list. Note that
if you change a port from static to continuous learn mode, the port retains in
memory any authorized addresses it had while in static mode. If you subse-
quently attempt to convert the port back to static mode with the same
authorized address(es), the Inconsistent value message appears
because the port already has the address(es) in its Authorized list.)
The Address Limit has not
been reached.
Although the Address
Limit is set to 2, only
one device has been
authorized for this port.
In this case you can add
another without having
to also increase the
Address Limit.
The Address Limit has been
reached.
!FishSecurity.book Page 12 Thursday, October 10, 2002 9:19 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve Switch 2650 and is the answer not in the manual?

HP ProCurve Switch 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
LayerLayer 2
Form FactorRack-mountable
Flash Memory8 MB
Jumbo Frame SupportYes
Power SupplyInternal
ManagementWeb, CLI, SNMP
FeaturesVLAN support, IGMP snooping, QoS
Operating Temperature0°C to 45°C (32°F to 113°F)
Operating Humidity15% to 95% (non-condensing)
Ports48 x 10/100
MAC Address Table Size8, 000 entries