2 Health LED Solid green Normal
Flashing green iLO is rebooting
Flashing amber System degraded
Flashing red System critical
3 NIC status LED Solid green Linked to network
Flashing green Network active
Off No network activity
4 UID button/LED Solid blue Activated
Flashing blue
1 flash per second = Remote management
or firmware upgrade in progress
4 flashes per second = iLO manual reboot
sequence initiated
8 flashes per second = iLO manual reboot
sequence in progress
Off Deactivated
ItemItem DescriptionDescription StatusStatus DefinitionDefinition
When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see
Front panel LED power fault codes
.
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the
front I/O cable is disconnected.
If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use
HPE
iLO to review the system health status.
1