Table 50 Error codes (part code 6005) (continued)
Severity LevelRecommended ActionError MessageError
Number
Part
Code
WCheck if the input number of
R-VOL is correct. If not, enter
the correct R-VOL number. If
the number is correct, vary
the specified path offline.
Specified R-VOL is still online from
HOST.
87496005
WConfirm the RCU controller
emulation type.
Remote Copy is not supported under
the RCU controller emulation type.
87516005
EPlease contact HP Technical
Support.
An internal error occurred.87536005
WCheck the serial number or
SSID of MCU, then retry with
correct parameter.
Invalid MCU serial number or MCU
SSID.
87546005
WCheck the serial number,
SSID or CU number of the
RCU, and retry the operation
with correct parameters.
Check the connection LCP
ports of the RCU. Connect
the path correctly, and retry
the operation
The serial number, SSID or CU number
of the RCU is invalid.
87556005
WCheck the storage system
cache status of the MCU
from the host. If it is off, set
it on and retry. If it cannot
be set on, please contact HP
Technical Support.
MCU disk array cache is not active.87566005
EThere is an invalid cache or
shared memory status on the
MCU. Check the status and
recover the cache or shared
memory, then retry the
operation.
One side of the Cache or shared
memory on the MCU is blocked.
87576005
EPlease contact HP Technical
Support.
Unexpected error on MCU.87586005
WPlease contact HP Technical
Support.
RCU Subsystem Cache status is not
active.
87596005
WCheck the track formats of
the specified M-VOL and
R-VOL.
M-VOL and R-VOL Track Formats do not
match.
87606005
Part code 6005 145