Table 62 Error codes (part code 7105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the RAID level, and specify a
volume of the supported RAID level, then
retry the operation.
The RAID level of the specified volume
is not supported.
86007105
WCheck the contents, and retry.The specified S-VOL cannot be paired
with a backup server volume.
86017105
WThe volume used as T-VOL of the other
pair cannot be used as S-VOL.
The command has been rejected,
because the specified S-VOL has already
been used as T-VOL of the other pair.
86027105
WCheck the pair status.The Resync command was issued to a
device in the simplex status.
86057105
WWhen the S-VOL of L1 pair is used as
the M-VOL of Continuous Access
Synchronous Z pair, L2 pair cannot be
created.
The operation to create L2 pair has been
rejected, because the S-VOL of L1 pair
is used as the M-VOL of Continuous
Access Synchronous Z pair.
86067105
WThe requested command cannot be
executed in the current status of
Continuous Access Synchronous Z pair.
See the section "Sharing Business Copy
Z volumes" in the HP StorageWorks
P9000 Business Copy for Mainframe
Systems User Guide for the relation
between the state of Continuous Access
Synchronous Z pair and the Business
Copy Z operations.
The command has been rejected,
because the specified T-VOL is used as
M-VOL of Continuous Access
Synchronous Z pair.
86077105
WRefresh the window, and retry the
operation.
The specified T-VOL is not defined.86087105
WCheck the status of the volume.The specified volume is not set as a
reserved volume.
86097105
WRelease the Auto LUN setting.The T-VOL is a target volume for Auto
LUN.
86107105
WCheck the status of the volume.The specified volume is a T-VOL.86117105
WCheck the status of the volume.The specified volume is not a T-VOL.86127105
WSpecify a volume of the supported RAID
level.
The RAID level of the specified T-VOL is
not supported.
86137105
WThe requested command cannot be
executed in the current status of
Continuous Access Synchronous Z pair.
See the section "Sharing Business Copy
for Mainframe volumes" in the HP
StorageWorks P9000 Business Copy for
Mainframe Systems User Guide for the
relation between the state of Continuous
Access Synchronous Z pair and the
Business Copy Z operations.
The command has been rejected,
because the specified T-VOL is used as
M-VOL of Continuous Access
Synchronous Z pair.
86147105
WThe R-VOL of Continuous Access
Synchronous Z pair cannot be used as
T-VOL of Business Copy Z.
Specify another volume.
The command has been rejected,
because the specified T-VOL is used as
R-VOL of Continuous Access Synchronous
Z pair.
86157105
258 Message (part code group 7nnn)