44
a. Save the configuration.
b. Shut down the IRF physical interfaces.
c. Change the operation mode from IRF to standalone after the IRF fabric splits.
201507090504
Symptom: When a PoE profile is configured, the router warns that the maximum PI power
specified by using the poe max-power command is invalid even if the value is in the valid
power range.
Condition: None.
201508120439
Symptom: The router reboots unexpectedly if the router is deleted from IMC.
Condition: This symptom might occur if the following conditions exist:
The router connects to IMC through a tunnel and passes portal authentication.
The router is deleted from IMC after portal authentication.
201508050381
Symptom: MAC address check on a DHCP relay agent does not take effect after DHCP is
disabled.
Condition: This symptom might occur if DHCP is disabled.
201507130082
Symptom: The router reboots unexpectedly if the HMIM-2/4/8GE module is repeatedly
rebooted when the module receives traffic.
Condition: This symptom might occur if the HMIM-2/4/8GE module is repeatedly rebooted when
the module receives traffic.
201508180093
Symptom: Two terminals in the same 3G or 4G network cannot communicate with each other.
Condition: This symptom might occur if the terminals are assigned the same network segment
but different subnet masks.
201508240276
Symptom: The router does not display the legal banner before authentication when an SSH
user logs in to the router.
Condition: None.
201508240106
Symptom: Some interfaces on the HMIM-2/4/8E1T1-F module cannot come up.
Condition: None.
201507300132
Symptom: Though the fixed Ethernet interfaces of the MSR2004 router are up, they cannot
receive packets.
Condition: This symptom occurs after the MSR2004 router has been operating for a certain
period of time.
201507240120
Symptom: Very rarely, the fixed GE0/1 or GE0/2 of MSR2004 router can't UP, and the interface
can't receive and send the packets (this occurs in a very small percentage of BCM5221 chips).
Condition: None.