Installing a DIMM blankInstalling a DIMM blank
About this taskAbout this task
Use the following table to decide if the thermal restrictions of the server require DIMM blanks in all open slots of your configuration.
Processor TDPProcessor TDP DIMM blank installationDIMM blank installation
105W to 140W Recommended
230W to 270W Recommended
150W to 270W Required
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
4. Remove the access panel .
5. Open the DIMM slot latches.
6. Install the DIMM blank.