EasyManua.ls Logo

HPE ProLiant DL380 Gen10 Plus - Installing a Front 8 Nvme Drive Cage

HPE ProLiant DL380 Gen10 Plus
315 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing a front 8NVMe drive cageInstalling a front 8NVMe drive cage
PrerequisitesPrerequisites
High-performance fans are required when installing this option.
About this taskAbout this task
The drive cage can be installed in any box. This procedure covers installing the drive cage in box 1.
ProcedureProcedure
1. Observe the following alerts.
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation
procedure. Improper grounding can cause ESD.
2. Power down the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Remove the air baffle .
6. Remove the fan cage.
7. Remove the blank.
8. Install the drive cage:
a. Remove all drive blanks .
b. Install the drive cage.
Installing a front 8NVMe drive cage 158

Table of Contents