EasyManua.ls Logo

HPE ProLiant DL560 Gen10 - Preventing Electrostatic Discharge; Preparation Procedures; Power down the Server; Extend the Server from the Rack

HPE ProLiant DL560 Gen10
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you must follow when setting up the system or handling parts.
A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
This type of damage may reduce the life expectancy of the device.
Procedure
• Avoid hand contact by transporting and storing products in static-safe containers.
• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
• Place parts on a grounded surface before removing them from their containers.
• Avoid touching pins, leads, or circuitry.
• Always be properly grounded when touching a static-sensitive component or assembly.
Preparation procedures
Power down the server
Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical server data and
programs.
IMPORTANT: When the server is in standby mode, auxiliary power is still being provided to the system.
To power down the server, use one of the following methods:
• Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby mode.
• Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS. If an application
stops responding, you can use this method to force a shutdown.
• Use a virtual power button selection through iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode.
Before proceeding, verify that the server is in standby mode by observing that the system power LED is amber.
Extend the server from the rack
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized
before extending a component from the rack.
1. Pull down the quick release levers on each side of the server.
2. Extend the server from the rack.
42
Removal and replacement procedures

Table of Contents

Other manuals for HPE ProLiant DL560 Gen10

Related product manuals