To replace the component, reverse the removal procedure.
Removing and replacing an NVDIMM
CAUTION: Do not remove an NVDIMM when any LEDs on any NVDIMM in the system are illuminated. Removing an
NVDIMM when an LED is illuminated might cause a loss of data.
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are properly grounded before
beginning this procedure.
CAUTION: Failure to properly handle DIMMs can cause damage to DIMM components and the system board connector.
To identify NVDIMMs installed in the server, see NVDIMM identification
Prerequisites
Before replacing memory, read the memory configuration and population guidelines in the server user guide.
NOTE: To support NVDIMMs, you must install two HPE Smart Storage batteries.
Procedure
1. Observe
NVDIMM relocation guidelines.
2. Power down the server (Power down the server).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following: