• Manually retrieve the HPE Persistent Memory module passwords from the server (user-generated passwords only)
• Export a password file to a USB key.
Hewlett Packard Enterprise recommends exporting the password file to a USB key.
For more information, see the HPE Persistent Memory User Guide on the Hewlett Packard Enterprise website (https://
www.hpe.com/info/persistentmemory-docs).
Procedure
1. Power down the server (
Power down the server).
2. Remove all power.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack (
Extend the server from the rack).
• Remove the server from the rack (Removing the server from the rack).
4.
Remove the access panel (
Removing the access panel).
5.
If installed, do the following:
a.
Remove the air bale (Removing and replacing the air bale).
b.
Remove the processor mezzanine tray (Removing and replacing the processor mezzanine tray).
c.
Remove the CPU Mezzanine UPI performance kit (
Removing and replacing the CPU Mezzanine UPI performance
kit).
6.
Remove the fan cage (
Removing and replacing the fan cage).
7.
Remove the smart storage batteries (Removing and replacing an energy pack).
8.
Remove the PCIe riser cages (Removing and replacing a PCIe riser cage).
9.
Remove the FlexLOM (
Removing and replacing the FlexibleLOM).
10.
Disconnect all cables connected to the system board.
11. Remove the system board:
a. Remove the screws from the side of the server.
b. Loosen the thumbscrew.
c. Slide the system board toward the front of the server, and then lift it from the server.
94
Removal and replacement procedures

Table of Contents