To replace the component, reverse the removal procedure.
Removing and replacing the non-hot-plug power supplyRemoving and replacing the non-hot-plug power supply
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply and the power supply blank to
cool before touching them.
About this taskAbout this task
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up.
HPE ProLiant ML30 Gen10 Plus Server Maintenance and Service Guide 53