Pools pools-1 OK
Controller 1 5001438025A26200 OK
# hardware show status CZ3320E200
Name Dev-id Status
----------------------- ---------------------- --------
Enclosure CZ3320E200 DEGRADED
Drawer 1 50014380308ADB00 DEGRADED
Drawer 2 50014380308ADB80 OK
PowerSupplies powerSupplies-1–2 OK
# hardware show status 50014380308ABE00
Name Dev-id Status
----------------------- ---------------------- --------
Drawer 1 50014380308ABE00 DEGRADED
Disk 5000C50059001B57 5000C50059001B57 OK
Disk 5000C50059065D1F 5000C50059065D1F OK
Disk 5000C500590686F7 5000C500590686F7 OK
- Drive_Missing_b10000d9 MISSING
Disk 5000C50059067767 5000C50059067767 OK
Disk 5000C50059001F3B 5000C50059001F3B OK
Disk 5000C5005906620F 5000C5005906620F OK
Disk 5000C5005907D57B 5000C5005907D57B OK
Disk 5000C5005906811B 5000C5005906811B OK
Disk 5000C5005906790B 5000C5005906790B OK
Disk 5000C5005906ACC7 5000C5005906ACC7 OK
Disk 5000C5005906A0E7 5000C5005906A0E7 OK
Disk 5000C500590822FB 5000C500590822FB OK
Fans fans-1-1 OK
TemperatureSensors tempsensors-1-1 OK
IOModule IOModule-1-1 OK
3. When you reach the faulty component, use the following command to display details and look at the
diagnostic message for more information. hardware show status <Dev-id> details
4. After identifying the issue to be corrected, follow the instructions in the relevant chapter of this guide.
5. Be sure to check that all problems have been resolved. Rerun the StoreOnce CLI command: hardware
show problems
The output returned should now be blank.
Identifying problems 19