Online Activity LED (green) Fault/UID LED (amber/blue) Interpretation
Flashing regularly (1 Hz) Amber flashing regularly
Do not remove the drive.
Removing a drive may terminate
the current operation and cause
data loss.
The drive is part of an array that is
undergoing capacity expansion or
a stripe size migration, but a
predictive failure alert has been
received for this drive. To minimize
the risk of data loss, do not
replace the drive until the
expansion or migration is
complete.
Flashing regularly (1 Hz) Off
Do not remove the drive.
Removing a drive may terminate
the current operation and cause
data loss.
The drive is rebuilding, or it is part
of an array that is undergoing
array expansion, logical drive
extension, a stripe size migration,
or RAID migration.
Flashing irregularly Amber flashing regularly (1 Hz) The drive is active, but a predictive
failure alert has been received for
this drive. Replace the drive as
soon as possible.
Flashing irregularly Off The drive is active and it is
operating normally.
Off Off A critical fault condition has been
identified for this drive and the
controller has placed it offline.
Replace the drive as soon as
possible.
Off Amber flashing regularly A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
Off Off The drive is offline, a spare, or not
configured as part of an array.
1 GbE LAN port LEDs
The 1 GbE LAN ports have two LEDs, as illustrated on the rear of the server below.
50 1 GbE LAN port LEDs