I-V600
EN - 41
If, with the remote unit active and
connected (even in recording
mode), the instrument detects an
irradiance value below the
threshold (see § 5.2), it stops the
test and returns to the main
screen. Check the threshold value
and carry out the tests at another
time of the day with stable
irradiation
If the instrument detects a short-
circuit current Isc below a
threshold limit, it does not
perform the test and displays the
message shown in the screen
alongside. Check the connections
of the instrument, the functionality
of the module/string, the module
settings and the number of
modules
In the I-V curve measurement, if
the current detected at the Voc
point (no-load situation) is greater
than 0.2A, the instrument does not
perform the test and displays the
message shown in the screen
alongside. Check the circuit being
measured and repeat the test.