Data
Table 4-5 describes the required parameters.
Table 4-5 Data list
Parameter Example Value
IP Address CX911: 192.168.1.100
CX912: 10.77.77.77
Subnet mask 255.255.255.0
Default gateway 0.0.0.0
The default username of the switching plane is root, and the default password is
Huawei12#$.
NO TE
You can query and set IP addresses of all modules. For details, see 8.11 Logging In to the
MM910 WebUI.
For the MM910 versions earlier than (U54) 2.20, choose System Management >
Network Management >
xx
> IP addresses.
For the MM910 (U54) 2.20 or later, choose Chassis Settings > Network Settings >
xx
.
Software Tools
wftpd32.exe: used to transfer les between dierent platforms, for example, from
a PC to a switch module. This tool is third-party software. You need to prepare it
by yourself.
Procedure
Step 1
Congure the FTP server.
For detailed about the conguration operations, see 8.20 Conguring an FTP
Server.
Step 2 Congure the IP address of the management network port.
1. After logging in to the switch module by using a serial port or the SOL
function, run the following commands on the switching plane CLI to query
and set the IP address of the management network port so that the switch
module can properly communicate with the FTP server:
NO TE
Skip this step if you log in to the switch module by using a network port.
<Fabric>system-view
[Fabric]interface MEth 0/0/1
[Fabric-MEth0/0/1]ip address
192.168.100.123 24
[Fabric-MEth0/0/1]display this
#
interface MEth0/0/1
Huawei Servers
Troubleshooting 4 Collecting Information
Issue 20 (2020-09-25) Copyright © Huawei Technologies Co., Ltd. 21