LUNA2000-200KWH-2H1 Smart String ESS
User Manual
4 SmartLogger Web-based Deployment
Copyright © Huawei Technologies Co., Ltd.
105
4 SmartLogger Web-based Deployment
Prerequisites
1. All devices onsite have been commissioned.
2. The system is powered on and alarms are cleared.
3. The commissioning equipment is available onsite.
4. Before the deployment, wait until the air conditioner adjusts the temperature inside the
cabinet and the temperature of batteries to the specified temperature range (5°C to 45°C).
4.1 Preparations and WebUI Login
Prerequisites
The operating system of Windows 7 or later is supported.
Browser: Chrome 52, Firefox 58, or Internet Explorer 9, or a later version is
recommended.
Procedure
Step 1 Connect the network cable between the network port of the PC and the WAN or LAN port of
the SmartLogger.
Step 2 Set the IP address for the PC on the same network segment as the SmartLogger IP address.
Connected
Port
Item
SmartLogger
Default Value
Example PC Setting
LAN port
IP address
192.168.8.10
192.168.8.11
Subnet mask
255.255.255.0
255.255.255.0
Default gateway
192.168.8.1
192.168.8.1
WAN port
IP address
192.168.0.10
192.168.0.11
Subnet mask
255.255.255.0
255.255.255.0
Default gateway
192.168.0.1
192.168.0.1