94 – English
Fault Possible
cause
Steps Troubleshooting Action
PTO
activation
does not
work
Battery
voltage
37 Check the 5A “Fuse P.T.O.” Replace fuse
38 Measure the voltage on J6 (pin 3) with the key in
“ON” position. The voltage should be equal to the
battery voltage.
Go to steps 3-6.
39 Measure the voltage in the connector to the electrical
coupling. The voltage should be equal to the battery
voltage when PTO is engaged.
Go to wiring fault
Wiring fault 40 Check the gray cable and connectors from J1 (pin 9)
on the control board to the PTO clutch.
Repair the cable or
replace the cabling.
41 Check the blue cable and connectors from the PTO
clutch to the battery.
42 Check the yellow cable and connectors from J6
(pin 3) on the control board to the PTO switch.
43 Check the yellow cable and connectors from J6
(pin 6) on the control board to the PTO switch.
Machine
will not shut
down
Wiring fault 44 Check the black cable and connectors between J1
(pin 6) and the engine.
45 Check the black cable and connectors between J7
(pin 5) and the key switch.
46 Check the blue cable and connectors between J7
(pin 6) and the key switch.
Key switch 47 Check that the black cable from connector J7 (pin 5)
and the blue cable from J7 (pin 6) makes contact
when the key is in “OFF" position.
Replace the key switch
12V socket
not working
Battery
voltage
48 Make sure the switch for the 12V socket is on. Enable the 12V socket
49 Check that the key switch is in the “ON” position. Turn the key switch to
“ON”.
50 Check the 5A “Fuse Power socket”. Replace fuse
51 Check steps 3-6. -
Wiring fault 52 Check the blue and black cable and contacts from J4
to the 12V socket.
Repair the cable or
replace the cabling
53 Check the red cables and connectors from J5 to the
switch for enabling the 12V socket.
Lamp not
working
Blown bulb 54 Try swapping bulbs or t a new. Replace the bulb
Wiring fault 55 Check the gray cables and connectors to the
malfunctioning lamp.
Repair the cable or
replace the cabling
Both lamps
not working
Battery
voltage
56 Make sure the switch for the lamps is activated. Activate the button
57 Check the 5A “Fuse Light”. Replace fuse
58 Measure the voltage on J2 (pin 3) with the key in
“ON” position. The voltage should be equal to the
battery voltage.
Check steps 3-6.
Wiring fault 59 Check the orange and blue cable and connectors
from J2 to the switch for the lamps.
Repair the cable or
replace the cabling
60 Check the cabling as in step 10 and step 11.
Appendices and schedules