2-4 MAX200 Instruction Manual
1-97
SPECIFICATIONS
Plasma Gases .....................................................Air, Oxygen (O
2
), Nitrogen (N
2
),
Argon/Hydrogen (H35 = 35% Hydrogen/65% Argon)
Shield Gases .......................................................Air, Carbon Dioxide (CO
2
), Nitrogen (N
2
)
Plasma Gas Flow ................................................66 scfh (Air), 60 scfh (N
2
), 70 scfh (H35), 72 scfh (O
2
)
Shield Gas Flow ...................................................220 scfh (CO
2
), 280 scfh (Air), 290 scfh (N
2
)
Plasma Gas Inlet Pressure .................................90/120 psi dynamic (flowing)
Shield Gas Inlet Pressure ...................................90 psi dynamic (flowing)
Plasma Gas Pressure (Test/Run).........................13/48, 22/48 psi (Air); 13/44, 15/48 psi (O
2
); 15/35,
17/37 psi (N
2
); 23/56 psi (H35)
Shield Gas Pressure ...........................................70 psi
Torch Coolant Tank Capacity ............................2.9 gallons (11 liters); refer to Section 3, Torch Coolant
System, for coolant specifications, warning, and cautions
CE Power Supplies
The specifications specific to the 400V CE, 3 Ph, 50 Hz power supplies (073200 and 073213) are listed below.
These CE power supplies conform to all other non CE power suppy specifictions as listed above. Refer to the
Appendix E for EMC requirements, power cable connections, and parts information specific to the MAX200 CE
power supplies.
Input Power (Input Voltage (U
1
) x Input Current (I
1
)):
# 073200 (without THC) .......................................400 VAC, 3Ø, 50 Hz, 56 amps
# 073213 (with THC) ............................................400 VAC, 3Ø, 50 Hz, 56 amps
Dimensions:
Height...................................................................40-3/4" (104 cm) w/o casters
48.25" (122 cm) w/casters
Weight ..................................................................800 pounds (363 kg)