MAX200 Instruction Manual 4-41
OPERATION
PAC200E Hand Torch
Stainless Steel Gouging
200 amps
H35 Plasma / N
2
Shield
Hypertherm recommends a mixture of 35% hydrogen and 65% argon for the plasma gas.
1 inch = 25.4 mm; 1 scfh = 28.316 liter/hour; 1 psi = .0689 bar = 6.895 KPa
* If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
Plasma
Gas
Type
Plasma Gas
Pressure
TEST/RUN
Shield
Gas
Type
Shield
Gas
Pressure
Arc
Current
Setting
Plasma
Gas Inlet
Pressure
Shield
Gas Inlet
Pressure
(psi) (psi) (amps) (psi) (psi)
H35
49-51* / 50-52
N
2
50 200 120 120
020891
Shield
020934
Nozzle
020882
Retaining cap
020933
Electrode
020607
Swirl ring

Table of Contents