EasyManua.ls Logo

Hypertherm Powermax 65 - Page 100

Hypertherm Powermax 65
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TORCH SETUP
3-54
powermax
65/85
Operator Manual
45A Unshielded Air flow rate - slpm/scfh
Aluminum
Hot 147 / 310
Cold 210 / 450
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
1
1.5 3.8 250
0.0 7400 126 12700 119
2 0.1 4400 127 11500 119
3 0.2 2800 129 7800 122
4 0.4 2100 132 5850 123
6 0.5 1050 135 2800 126
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
1/32 in
0.06 0.15 250
0.0 325 126 500 120
1/16 in 0.1 200 126 500 116
3/32 in 0.2 150 127 410 122
1/8 in 0.4 100 130 280 122
1/4 in 0.5 36 136 90 126

Table of Contents