TORCH SETUP
3-52
powermax
65/85
Operator Manual
45A Unshielded Air flow rate - slpm/scfh
Mild Steel
Hot 147 / 310
Cold 210 / 450
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
0.5
1.5 3.8 250
0.0
9000 120 12700 122
1 9000 120 12700 122
1.5 0.1 7700 120 12700 122
2 0.3 6150 119 9750 120
3
0.4
3950 121 6150 122
4 2350 123 4450 124
6 0.5 1400 126 2550 123
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
26GA
0.06 0.15 250
0.0
350 120 500 122
22GA 350 120 500 122
18GA
0.1
350 119 500 122
16GA 300 121 500 122
14GA 0.2 250 119 400 120
12GA
0.4
200 120 270 122
10GA 100 123 205 123
3/16 in 0.5 85 122 135 125
1/4 in 0.6 48 127 91 122