Serial Communication Programmer Reference Guide
38 810400 Reference Guide Powermax65/85/105 SYNC
Response from plasma power supply:
:01053180000049<CR><LF>
Do a quick restart or clear fault code 0-50-0
Before you change a cartridge, you must set the torch-disable switch to the yellow lock (X) position.
Otherwise you get fault code 0-50-0 (the cartridge is off the torch). To clear fault code 0-50-0 after
you install the new cartridge, do a quick restart.
To do a quick restart, the CNC must write values to the following registers:
0x308E (quick restart command)
0x308F (quick restart approval)
To give sufficient time for the plasma power supply to complete the
restart, wait 2 seconds before you send a new read or write request.
0x308E, 0x308F (quick restart with approval)
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
05 Write Single Coil (confirmed)
3180 Coil address (0x3180) (confirmed)
0000 Value to write to coil address 0x3180 (0x0000 = OFF) (confirmed)
49 LRC
<CR><LF> End
Description: Write a value of 0x0404 to address 0x308E and a value of 0x0618 to address
0x308F to do a quick restart.
Encoding or scaling: N/A
Unit: N/A
Function (hex): 10 (Write Multiple Registers)