Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 27
Example request and response
Request from CNC:
:010430010005C5<CR><LF>
Response from plasma power supply:
:01040A020107800B401D002700D8<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address
04 Read Registers
3001 First register address
0005 Quantity of registers to read (0x0005 =5):
• 0x3001 (permitted operating mode setting)
• 0x3002 (permitted minimum output current (A) setting)
• 0x3003 (permitted maximum output current (A) setting)
• 0x3004 (permitted minimum gas pressure setting)
• 0x3005 (permitted maximum gas pressure setting)
C5 LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
04 Read Registers (confirmed)
0A Quantity of bytes in the Data segment (0x0A = 10)
0201 02 = 0x02 = expanded metal
01 = 0x01 = cut
0780
0B40
0x0780 = 1920/64 = 30 A
0x0B40 = 2880/64 = 45 A
1D00
2700
0x1D00 = 7424/128 = 58 psi
0x2700 = 9984/128 = 78 psi
D8 LRC
<CR><LF> End