Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 27
Example request and response
Request from CNC:
:010430010005C5<CR><LF>
Response from plasma power supply:
:01040A020107800B401D002700D8<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address
04 Read Registers
3001 First register address
0005 Quantity of registers to read (0x0005 =5):
0x3001 (permitted operating mode setting)
0x3002 (permitted minimum output current (A) setting)
0x3003 (permitted maximum output current (A) setting)
0x3004 (permitted minimum gas pressure setting)
0x3005 (permitted maximum gas pressure setting)
C5 LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
04 Read Registers (confirmed)
0A Quantity of bytes in the Data segment (0x0A = 10)
0201 02 = 0x02 = expanded metal
01 = 0x01 = cut
0780
0B40
0x0780 = 1920/64 = 30 A
0x0B40 = 2880/64 = 45 A
1D00
2700
0x1D00 = 7424/128 = 58 psi
0x2700 = 9984/128 = 78 psi
D8 LRC
<CR><LF> End

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals