Serial Communication Programmer Reference Guide
54 810400 Reference Guide Powermax65/85/105 SYNC
Example request and response
Request from CNC:
:01043044000483<CR><LF>
Response from plasma power supply:
:010408007900790000000001<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address
04 Read Registers
3044 First register address (0x3044)
0004 Quantity of registers to read (0x0004 = 4):
• 0x3044 (fault log 0)
• 0x3045 (fault log 1)
• 0x3046 (fault log 2)
• 0x3047 (fault log 3)
83 LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
04 Read Registers (confirmed)
08 Quantity of bytes in the Data segment (0x08 = 8)
0079 0x0079 = 0121 = fault code 0-12-1 (output gas pressure is low) (newest fault)
0079 0x0079 = 0121 = fault code 0-12-1 (output gas pressure is low)
0000 0x0000 = 0000 = 0-00-0 (no fault code)
0000 0x0000 = 0000 = 0-00-0 (no fault code) (oldest fault)
01 LRC
<CR><LF> End