Serial Communication Programmer Reference Guide
48 810400 Reference Guide Powermax65/85/105 SYNC
Read the 16-character UID number for the installed cartridge
To read the unique identification (UID) number for the installed cartridge, the CNC reads the values
in the following registers:
0x3030 (UID, bytes 0 and 1)
0x3031 (UID, bytes 2 and 3)
0x3032 (UID, bytes 4 and 5)
0x3033 (UID, bytes 6 and 7)
0x3034 (UID, bytes 8 and 9)
0x3035 (UID, bytes 10 and 11)
0x3036 (UID, bytes 12 and 13)
0x3037 (UID, bytes 14 and 15)
0x3030 0x3037 (cartridge UID, bytes 0 15)
Description: Reads the hexadecimal value for the 16-character ASCII UID for the installed
cartridge.
Convert the hexadecimal values to ASCII.
A hexadecimal value of 00000000000000000000000000000000 indicates a
cartridge communication failure or radio frequency error.
Encoding or scaling: N/A
Unit: N/A
Function (hex): 04 (Read Registers)