Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 53
0x3045 (fault log 1)
0x3046 (fault log 2)
0x3047 (fault log 3)
Description: Reads the hexadecimal value of the fault code for the second most-recent fault for
the installed cartridge. If there is no fault, this reads a value of 0x0000 (0-00-0).
Convert the hexadecimal value to decimal.
Refer to Fault code list on page 32 for the complete list of possible fault codes.
Encoding or scaling: 10-bit effective unsigned binary number from the LSB of a 16-bit binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value of the fault code for the third most-recent fault for the
installed cartridge. If there is no fault, this reads a value of 0x0000 (0-00-0).
Convert the hexadecimal value to decimal.
Refer to Fault code list on page 32 for the complete list of possible fault codes.
Encoding or scaling: 10-bit effective unsigned binary number from the LSB of a 16-bit binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value of the fault code for the fourth most-recent fault for
the installed cartridge. If there is no fault, this reads a value of 0x0000 (0-00-0).
Convert the hexadecimal value to decimal.
Refer to Fault code list on page 32 for the complete list of possible fault codes.
Encoding or scaling: 10-bit effective unsigned binary number from the LSB of a 16-bit binary number
Unit: N/A
Function (hex): 04 (Read Registers)