Serial Communication Programmer Reference Guide
58 810400 Reference Guide Powermax65/85/105 SYNC
Example request and response
Request from CNC to read 1 coil:
:010131000001CC<CR><LF>
Response from plasma power supply for a read of 1 coil:
:01010100FD<CR><LF>
Request from CNC to read both coils at one time:
:010131000002CB<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address
01 Read Coil
3100 Coil address (0x3100)
0001 Quantity of coils to read (0x0001 = 1):
0x3100 (Start switch signal status)
CC LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
01 Read Coil (confirmed)
01 Quantity of bytes in the Data segment (0x01 = 1)
00 0x00 = 0 (binary) = OFF (Start input is OFF)
FD LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address
01 Read Coil
3100 Coil address (0x3100)
0002 Quantity of coils to read (0x0002 = 2):
0x3100 (Start switch signal status)
0x3101 (Motion switch signal status)
CB LRC
<CR><LF> End