Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 59
Response from plasma power supply:
:01010103FA<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
01 Read Coil (confirmed)
01 Quantity of bytes in the Data segment (0x01 = 1)
03 0x03 = 11 (binary) =
• 1 (binary) = ON (Start input is ON)
• 1 (binary) = ON (Motion input is ON)
FA LRC
<CR><LF> End