Serial Communication Programmer Reference Guide
46 810400 Reference Guide Powermax65/85/105 SYNC
0x302D (total number of arc transfers bytes 3 and 2)
0x302E (cumulative arc transfer time bytes 1 and 0)
0x302F (cumulative arc transfer time bytes 3 and 2)
Description: Reads the hexadecimal value of the high word (bytes 3 and 2) for the total number
of arc transfers that the plasma power supply has done in its life.
You will need to interchange the hexadecimal values for 0x302C and 0x302D, and
then convert the result to decimal.
Encoding or scaling: 32-bit unsigned binary number
Unit: Number
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value of the low word (bytes 1 and 0) for the cumulative arc
transfer time in seconds that the plasma power supply has had in its life.
Refer to 0x302F (cumulative arc transfer time bytes 3 and 2).
Encoding or scaling: 32-bit unsigned binary number
Unit: Seconds
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value of the high word (bytes 3 and 2) for the cumulative
arc transfer time in seconds that the plasma power supply has had in its life.
You will need to interchange the hexadecimal values for 0x302E and 0x302F, and
then convert the result to decimal.
Encoding or scaling: 32-bit unsigned binary number
Unit: Seconds
Function (hex): 04 (Read Registers)