Serial Communication Programmer Reference Guide
Powermax65/85/105 SYNC Reference Guide 810400 37
Example request and response
Request from CNC to start a gas test:
:01053180FF004A<CR><LF>
Response from plasma power supply:
:01053180FF004A<CR><LF>
Request from CNC to stop a gas test:
:01053180000049<CR><LF>
Value Description
: Start of message
01 Plasma power supply node address
05 Write Single Coil
3180 Coil address (0x3180)
FF00 Value to write to coil address 0x3180 (0xFF00 = ON)
4A LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address (confirmed)
05 Write Single Coil (confirmed)
3180 Coil address (0x3180) (confirmed)
FF00 Value to write to coil address 0x3180 (0xFF00 = ON) (confirmed)
4A LRC
<CR><LF> End
Value Description
: Start of message
01 Plasma power supply node address
05 Write Single Coil
3180 Coil address (0x3180)
0000 Value to write to coil address 0x3180 (0x0000 = OFF)
49 LRC
<CR><LF> End