Serial Communication Programmer Reference Guide
50 810400 Reference Guide Powermax65/85/105 SYNC
Read the total cut counts for the installed cartridge
To read the total cut counts for the installed cartridge, the CNC reads the values in the following
registers:
0x3040 (total number of starts)
0x3041 (cumulative pilot arc time)
0x3042 (total number of arc transfers)
0x3043 (cumulative arc transfer time)
0x3040 (total number of starts)
0x3041 (cumulative pilot arc time)
0x3042 (total number of arc transfers)
Description: Reads the hexadecimal value for the total number of pilot arc starts that the
cartridge has done in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value for the cumulative pilot arc time in seconds that the
cartridge has had in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value for the total number of arc transfers that the cartridge
has done in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)