EasyManuals Logo
Home>Hypertherm>Welding System>Powermax65 SYNC

Hypertherm Powermax65 SYNC Reference Guide

Hypertherm Powermax65 SYNC
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #50 background imageLoading...
Page #50 background image
Serial Communication Programmer Reference Guide
50 810400 Reference Guide Powermax65/85/105 SYNC
Read the total cut counts for the installed cartridge
To read the total cut counts for the installed cartridge, the CNC reads the values in the following
registers:
0x3040 (total number of starts)
0x3041 (cumulative pilot arc time)
0x3042 (total number of arc transfers)
0x3043 (cumulative arc transfer time)
0x3040 (total number of starts)
0x3041 (cumulative pilot arc time)
0x3042 (total number of arc transfers)
Description: Reads the hexadecimal value for the total number of pilot arc starts that the
cartridge has done in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value for the cumulative pilot arc time in seconds that the
cartridge has had in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)
Description: Reads the hexadecimal value for the total number of arc transfers that the cartridge
has done in its life.
Convert the hexadecimal value to decimal.
Encoding or scaling: 16-bit unsigned binary number
Unit: N/A
Function (hex): 04 (Read Registers)

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals