EasyManuals Logo

IAI ASEP User Manual

IAI ASEP
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
64
/
3. Operation
No Name Initial Value Setting Range Remarks
19
Absolute Battery Retention
Time
2 0 to 3
Set the standard for the absolute data storage time.
Parameter
No.19 Setting
Encoder Max. Rotation
Speed [rpm]
Reference
for Battery
Retention
Time
(reference)
[day]
When the
connected
actuator is a
model other
than
RCA2-***N;
When the
connected
actuator is
RCA2-***N;
0 100 75 20
1 200 150 15
2 400 300 10
3 800 600 5
20
Position Data Change Password
0000 0000 to 9999 When “0000” is set, the password input is not required.
(Note 1) Please refer to the next section if the servo-motor gain adjustment is required.