Step 1521-12
Reconnect the ac power cable(s) to the power distribution unit.
Note: Read the Danger and Caution notices under “Safety Notices” on page xi before
continuing with this procedure.
Perform the following:
1. Disconnect the ac power cable from each power supply of the primary I/O drawer.
2. Use a multimeter to measure the ac voltage at the drawer end of each ac power
cable.
Is the ac voltage from 200 V ac to 240 V ac?
NO Replace the ac power cable(s).
This ends the procedure. Go to Map 0410: Repair Checkout in the
Diagnostics Information for Multiple Bus Systems
.
YES Go to “Step 1521-13” on page 95.