Firmware Error Codes
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 113 unless otherwise
indicated in the tables.
If you replace FRUs and the problem is corrected, go to MAP 410: Repair Checkout
in the
RS/6000 and
Eserver
pSeries Diagnostics Information for Multiple Bus Systems
.
Table 5. Firmware Error Codes.
Error Code Description Action/
Possible Failing FRU
2011 00xy I/O drawer power supply failure 1. Replace power supply “y” in I/O
drawer “x”.
If y=_, then the power supply is:
y = power supply
3 = Both power supplies
(I/O drawer)
2 = Reserved
1 = Reserved
See “AIX and Physical Location
Code Tables” in Chapter 1 for
location codes.
2. Check AC power source to I/O
drawer “x”.
See “AIX and Physical Location
Code Tables” in Chapter 1 for
location codes.
2022 0000 The I/O system is running slowly. 1. Check cabling
2. Call for support
190 Service Guide