Table 8. Common Firmware Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
B1FD 0015 Too many firmware update diskettes
inserted (or wrong or faulty update
image)
1. Assure the firmware update
image is correct for the specific
system type and model
2. Replace the update diskettes with
a new set of firmware update
diskettes.
B1FD 0016 Diskette read error 1. The firmware diskette may be
faulty. Try another diskette.
2. Replace the diskette drive.
3. Replace the primary I/O
backplane.
Location: U0.1-P1
B1FD 001A Service processor recovery mode
update fault
Reset service processor (by
activating pinhole reset switch or by
disconnecting, then reconnecting
power)
B1FD 001E Service processor recovery mode
update fault
Wrong firmware update diskette
(Insert correct diskette)
B1FD 001F Bad firmware update diskette Replace diskette
Scan Log Dump Progress Codes
Table 9. Scan Log Dump Progress Codes
Error Code Description Action/
Possible Failing FRU
D130 xxxx Scan log dump in progress Informational message only. As the
dump progresses, the xxxx
characters in the display will change.
When the scan log dump is
complete, the system may reboot,
depending on the reboot policy
settings.
Chapter 5. Error Code to FRU Index
363