Table 8. Common Firmware Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
B1xx 4695 System power control network to
service processor interface failure
1. Check for system firmware
update
2. Primary I/O backplane
Location: U0.1-P1
B1xx 4696 System firmware interface failure
1. Check for system firmware
update.
2. Call service support.
B1xx 4698 Firmware problem
1. Check for system firmware
update.
2. Call service support.
B1xx 4699 Service processor firmware 1. Check for system firmware
update
2. Call service support.
B1xx 469A System firmware interface 1. Check for system firmware
update
2. Call service support.
B1xx 469B Firmware to I/O interface 1. Check for system firmware
update
2. Primary I/O backplane
Location: U0.1-P1
B1xx 469C Firmware to I/O interface 1. Check for system firmware
update
2. Primary I/O backplane
Location: U0.1-P1
B1xx 469E Service processor firmware failure 1. Check for system firmware
update
2. Go to “MAP 1540: Minimum
Configuration” on page 113, CEC
minimum config
3. Primary I/O backplane
Location: U0.1-P1
B1xx 469F Service processor failure 1. Check for system firmware
update
2. Go to “MAP 1540: Minimum
Configuration” on page 113, CEC
minimum config
3. Primary I/O backplane
Location: U0.1-P1
B1xx 8FF0 Informational message No action required
B1FD 0013 A firmware update has failed because
the update image is invalid. The
update was aborted before any
changes were made to the currently
installed firmware.
Reset the service processor (by
activating the pinhole reset switch or
by disconnecting, then reconnecting
power). Install a valid firmware
update image for the specific system
type and model.
362 Service Guide