SPCN Error Codes
Attention: If a power supply or fan is hot-swapped, wait five minutes, then recheck
the AIX error log. If the system has to be shut down to replace a power supply or fan,
reboot the system, wait five minutes after the AIX login prompt appears, then recheck
the AIX error log. If the detailed information for the most recent error with the same
identifier indicates that the original problem has not been fixed by performing the first
action in the action column, continue with the next action in the action column.
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 113 unless otherwise
indicated in the tables.
If you replace FRUs and the problem is corrected, go to MAP 410: Repair Checkout
in the
RS/6000 and
Eserver
pSeries Diagnostics Information for Multiple Bus Systems
.
Table 4. SPCN Error Codes
Error Code Description Action/
Possible Failing FRU
1011 00AC AC loss or brownout detected Information message
1011 00EF Room emergency power off detected Information message
1011 1510 Power supply 1 power source failure 1. Check input power to the
power supply
2. Primary I/O drawer power
supply 1
Location: U0.1-V1
3. Primary I/O backplane
Location: U0.1-P1
1011 1511 Power supply 1 fault 1. Primary I/O drawer power
supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1512 Power supply 1 non-power fault 1. Primary I/O drawer power
supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1513 Power supply 1 domain fault 1. Primary I/O drawer power
supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
1011 1514 Power supply 1 cooling fault 1. Primary I/O drawer power
supply 1
Location: U0.1-V1
2. Primary I/O backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
169