Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 1516 Swapped power supply and cooling unit
or missing power supply 1
1. Verify correct installation of
primary power supply and
cooling unit
2. Primary I/O power supply 1
Location: U0.1-V1
1011 1520 Power supply 2 power source failure 1. Check input power to the
power supply
2. Primary I/O drawer power
supply 2
Location: U0.1-V2
3. Primary I/O backplane
Location: U0.1-P1
1011 1521 Power supply 2 fault 1. Primary I/O drawer power
supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1522 Power supply 2 non-power fault 1. Primary I/O drawer power
supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1523 Power supply 2 domain fault 1. Primary I/O drawer power
supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1524 Power supply 2 cooling fault 1. Primary I/O drawer power
supply 2
Location: U0.1-V2
2. Primary I/O backplane
Location: U0.1-P1
1011 1526 Power supply 2 missing Primary I/O drawer power supply 2
Location: U0.1-V2
1011 1611 CEC regulator 1 fault Processor card
Location: U1.1-P1-C1
1011 1612 CEC regulator 1 non-power fault 1. Processor card
Location: U1.1-P1-C1
2. Primary I/O backplane
Location: U0.1-P1
1011 1613 CEC regulator 1 domain fault Processor card
Location: U1.1-P1-C1
1011 1621 CEC regulator 2 fault Processor card
Location: U1.1-P1-C1