EasyManua.ls Logo

IBM 7026-H80 - RS/6000 - 256 MB RAM - Page 118

IBM 7026-H80 - RS/6000 - 256 MB RAM
557 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 1522-11
Note: Read the Danger and Caution notices under “Safety Notices” on page xi before
continuing with this procedure.
Perform the following:
1. Disconnect the ac power cable(s) from the power distribution unit that supplies
power to the CEC drawer.
2. Use a multimeter to measure the ac voltage at the power distribution unit socket(s)
where the ac power cable(s), just removed, was (were) attached.
Is the ac voltage from 200 V ac to 240 V ac?
NO Replace the power distribution unit.
This ends the procedure. Go to Map 0410: Repair Checkout in the
Diagnostics Information for Multiple Bus Systems
.
YES Go to “Step 1522-12”.
Step 1522-12
Reconnect the ac power cable(s) to the power distribution unit.
Note: Read the Danger and Caution notices under “Safety Notices” on page xi before
continuing with this procedure.
Perform the following:
1. Disconnect the ac power cable from each power supply of the CEC drawer.
2. Use a multimeter to measure the ac voltage at the drawer end of each ac power
cable.
Is the ac voltage from 200 V ac to 240 V ac?
NO Replace the ac power cable(s).
This ends the procedure. Go to Map 0410: Repair Checkout in the
Diagnostics Information for Multiple Bus Systems
.
YES Go to “Step 1522-13” on page 101.
100 Service Guide

Table of Contents

Related product manuals