Table 4. SPCN Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
1011 7640 Slow I/O drawer fan 4 1. Fan 4
Location: U0.1-F4
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
1011 7641 Missing I/O drawer fan 4 Fan 4
Location: U0.1-F4
1011 7650 Slow fan in primary I/O drawer power
supply 1
1. I/O drawer power supply 1
Location: U0.1-V1
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
1011 7651 Missing fan 5 in primary I/O drawer power
supply 1
I/O drawer power supply 1
Location: U0.1-V1
1011 7660 Slow fan in primary I/O drawer power
supply 2
1. I/O drawer power supply 2
Location: U0.1-V2
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
1011 7661 Missing fan 6 in primary I/O drawer power
supply 2
I/O drawer power supply 2
Location: U0.1-V2
1011 7690 Slow I/O drawer fan 9 in cooling unit 1. Fan 9 (cooling unit)
Location: U0.1-F9
2. Primary fan controller
Location: U0.1-X2
3. Power distribution card
Location: U0.1-X1
1011 7691 Missing I/O drawer fan 9 in cooling unit Fan 9 (cooling unit)
Location: U0.1-F9
1011 7710 Slow CEC fan 1 1. Fan 1
Location: U1.1-F1
2. CEC fan controller
Location: U1.1-X2
3. Power distribution card
Location: U1.1-X1
Chapter 5. Error Code to FRU Index
177