Table 6. Service Processor Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
4B2E 288D Processor system and scan control
routines detected memory riser fault
1. Go to service processor memory
configuration/deconfiguration
menu to verify memory DIMMs
state. See ″Memory
Configuration/Deconfiguration
Menu″ on page 384 for more
information.
2. Memory riser card
Locations:
U1.1-P1-M1
U1.1-P1-M2
4B2E 2A00 Processor system and scan control
routines detected 6W processor fault
Processor card
Location: U1.1-P1-C1
4B2E 300A Processor system and scan control
routines detected 32MB DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2E 300B Processor system and scan control
routines detected 128MB DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2E 300C Processor system and scan control
routines detected 256MB DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2E 300D Processor system and scan control
routines detected 512MB (stacked)
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2E 300E Processor system and scan control
routines detected 512MB (unstacked)
DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
4B2E 301F Processor system and scan control
routines detected 128MB DIMM fault
Memory DIMM
Locations:
U1.1-P1-M1.n
U1.1-P1-M2.n
U1.1-P1-C1-Mn
350 Service Guide