Page #188 background imageLoading...
Page #188 background image
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom Action
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail 5 error has
been recorded in the IMM
event log.
1. Disconnect the server power cords.
2. Remove the following components if the Pwr rail 5 error has been recorded in
the IMM event log:
v DVD drive (if one is installed)
v Fan 3
v Fan 4
v Hard disk drives
v DIMMs 13 through 18
3. Restart the server. If the Pwr rail 5 error has been recorded in the IMM event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 326 and “Replacing the system board” on page
330).
4. Reinstall the components one at a time, in the order shown, restarting the
server each time. If the Pwr Rail 5 error has been recorded in the IMM event
log again, the component that you just reinstalled is defective. Replace the
defective component.
v DIMMs 13 through 18 (see “Removing a memory module” on page 236 and
“Installing a memory module” on page 49).
v Hard disk drives
v Fan 4 (see “Removing a hot-swap fan” on page 266 and “Installing a
memory module” on page 49).
v Fan 3
v DVD drive, if one is present (see “Removing a DVD drive” on page 225 and
“Replacing a DVD drive” on page 227).
5. Follow actions in “Solving power problems” on page 175, if the OVER SPEC
LED on the light path diagnostics panel is still lit.
6. Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
170 IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
ProcessorIntel Xeon E5-2600 series
ChipsetIntel C600 series
MemoryUp to 768 GB
StorageUp to 8 x 2.5" hot-swap drives
Form Factor1U rack
Power Supply750 W AC
Network Interface4 x 1 GbE
RAID SupportRAID 0, 1, 10
Expansion Slots3 x PCIe 3.0 slots
Operating System SupportWindows Server, RHEL, SUSE, VMware
ManagementIntegrated Management Module II (IMM2)