Loading...
516-902-000 ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Failed
Explanation: A failure was detected while verifying operation of the status LEDs.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
DSA EXA port ping test results
The following messages can result when you run the EXA port ping test.
401-000-000 EXA Port Ping Test Passed
Explanation: EXA Port Ping Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
401-801-000 EXA Port Ping Test Aborted
Explanation: EXA Port Ping Test Aborted. Unable to get device base address.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Remove power cables, wait for 45 seconds, reconnect and rerun the test.
2. Make sure that the scalability cable connections are as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest level.
4. If the problem remains, contact your technical-service representative.
516-902-000 401-801-000