201-901-003 Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
5. Replace any DIMMS(s) mentioned in error, one by one.
6. Make sure that all DIMMs are enabled in the Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the
next corrective action.
DSA memory stress test results
The following messages can result when you run the memory stress test.
202-000-000 MemStr Test Passed
Explanation: Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
202-801-000 MemStr Test Aborted
Explanation: Internal program error.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the latest level.
3. Run the test again.
4. If the system has stopped responding, turn off and restart the system.
5. Check the system firmware level and upgrade if necessary.
6. Run the memory diagnostic to identify the specific failing DIMM.
7. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for
the next corrective action.
201-901-003 202-801-000
758
IBM System x3550 M4 Type 7914: Installation and Service Guide

Table of Contents

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M4
CategoryServer
LanguageEnglish

Related product manuals